Explosion-proof XRC-DP flange type

Explosion-proof XRC-DP flange type

Wide applicability: Measurement of liquid and solid powdered materials, complex process conditions
Detect stable: The components are securely connected, ensuring high reliability and minimal maintenance, generally requiring no repair.
Easy to use: -20°~70°C
anti-caking property: The range can be modified on-site, the number of decimal places can be adjusted, the unit names can be swapped between high and low pressure, the factory settings can be restored.
Special function: 4-20mA   3 switch points, 4-20mA   485 communication
Various outputs: G1, G3/4 threads (multiple installation methods such as chuck, flange, etc.)
Special function: Layered medium detection (oil-water interface detection can be set)
产品详情



Technical Parameters Table


Electricalparameters

Temperaturerange



Workingvoltage

20-30VDC

Mediumtemperaturerange

-20°~75°C(standardtype)

Workingcurrent

<80mA


-20°~200°C(HighTemperatureHeatSinkType)

Shortcircuitprotection(analogoutput)

Have


-70°~230°C(amplifierseparatetype)

PolarityProtection(AnalogOutput)

Have

Dielectricconstantofthemedium

≥1.8

0-10Voutput

Theloadisatleast500Ω.

Maximummediumpressure

3MPa(MaximumWithstandingVoltage)

0-20mAoutput

Loadupto500Ω

0~3.3nF


4-20mA output

Maximum load of 500 Ω

Storage temperature range


Switching output

PNP (NO/NC switchable)

Electrical interface


load current

Maximum 200mA (with short circuit protection)

Electrical interface

4-core M12 connector (analog output+1 switch)

Switch point setting

5~95% adjustable


5-core M12 connector (analog output+485 communication)

measurement accuracy

± 3% of the maximum measurement range


8-core M12 connector (analog output+3 switch values)

Repetitive accuracy

± 1% of the maximum measurement range



Protection level

IP67





Explosion proof mark: Ex ia Ⅱ C T6 Ga/ExIII Ⅱ C T80 ℃ Da

Technical document: Q/XRYB006-2023

Image number: XRC-DP.00

remarks:

1. The rated voltage is DC 24V, and the power supply needs to use an associated device that matches its intrinsic safety parameters. Intrinsic safety parameters: Ui: Dc28v, Ii: 93mA, Ci: rF, Li: 0H, Pi: 0.65W

2. Operating environment temperature: -20 ℃ STa<+60 ℃. Shell protection level: IP67.

3. The suffix "extinguished" indicates that there is a potential electrostatic charge hazard in non integral components of the casing. When maintaining, attention should be paid to: the equipment should be used in Zone 0 to prevent ignition hazards caused by impact or friction.

4. Associated inspection report number: 20245500096.

After reviewing the product drawings and technical documents mentioned above and inspecting the samples, it meets the following current national standards: GB/T 3836.1-2021, GB/T 3836.4-2021, GB/T 4208-2017




Liquid (or solid) medium; Oil based liquids with a dielectric constant higher than 1.8 can be measured, while water-based liquids with a dielectric constant higher than 80 can be measured with accuracy related to the absolute length of the probe.

Protection level and connecting devices; All products have a protection level of up to IP67. Conventional product configuration includes M12 connectors.

Temperature and pressure; The integrated liquid level sensor can work normally in an environment of -20 ° C to+70 ° C. The external amplifier's split type probe can withstand a maximum working temperature of 230 ° C, and the maximum pressure in the container cannot exceed 10 bar

Electrical wiring diagram





Products and Solutions
certificates
Products and Solutions
News
Press release
Office Address: Room 204, 2nd Floor, Building 1, No. 20, Ping&#039;an Road, Zhongancun West Artificial Intelligence Science and Technology Park, Mentougou District, Beijing
159-1098-6503 Manager Li / 156-2408-6688 Zhang
Factory Address: No.3 Workshop, No.3 Gate, Shandong Xinjiameng, Jiaxiang County, Jining City Shandong Province