Technical parameter table
Electrical parameters | temperature range |
|
|
working voltage | 20-30VDC | Medium temperature range | -20°~75°C (Common type) |
working current | <80mA |
| -20°~200°C (high temperature cooling neck type) |
Short-circuit protection (analog output) | have |
| -70°~230°C (amplifier split type) |
Antipolarity protection (analog output) | have | The medium dielectric constant | ≥1.8 |
0-10V output | Minimum load of 500 Ω | Media maximum pressure | 3MPa (maximum withstand pressure) |
0-20mA output | Maximum load of 500 Ω | Maximum capacitance measurement range | 0~3.3nF |
4-20mA output | Maximum load of 500 Ω | Storage temperature range |
|
Switch output | PNP (NO / NC switchable) | Electrical interface |
|
load current | Max. 200 mA (with short-circuit protection) | Electrical interface | 4-core M12 connector (analog output + 1 switch volume) |
Switch point setting | From 5 to 95% is adjustable |
| 5-core M12 connector (analog output + 485 communication) |
certainty of measurement | ± 3% of the maximum measurement range |
| 8-core M12 connector (analog output + 3 switches) |
repeatability precision | And ± 1% of the maximum measurement range |
|
|
levels of protection | IP67 |
|
|
|
| Explosion-proof sign: Ex ia ⅡC T6 Ga / ExIIIC T80℃ DaTechnical document: Q / XRYB006-2023Figure No.: XRC-DP.00remarks:1. Rated voltage DC 24V, the power supply should match the underlying safety parameters of the associated device, the underlying safety parameters: Ui:Dc28v,Ii:93mA,Ci:0rF,Li:0H,Pi:0.65W.2. Ambient temperature: -20℃ STa <+ 60℃. Housing protection level: IP67.3. The suffix "extinguish" indicates that the other parts of the shell have a potential electrostatic charge danger. Note during maintenance: the equipment is used in zone 0, and the ignition danger caused by impact or friction should be prevented.4. Association inspection Report No.: 2024550096.After the review of the above product drawings and technical documents and the inspection of the samples, they meet the following current national standards: GB / T 3836.1-2021, GB / T 3836.4-2021, GB / T 4208-2017 |
|
Liquid (or solid) medium; oily liquid with dielectric constant higher than 1.8 can be measured, and high dielectric constant (higher than 80) is related to the absolute length of the probe rod.
Protection class and connection devices; all products have protection grade up to IP67. General product configuration: the M12 connector.
emperature and pressure; integrated level sensor works normally in-20°~ + 70°C, the rod of external amplifier can bear a maximum operating temperature of 230°C, and the maximum pressure in the container shall not exceed 10bar
Electrical wiring diagram